TOPTICA Photonics AG - A passion for precision - www.toptica.com

SYS DC 110

Well-established analog driving electronics for tunable diode lasers

  • Supply rack with linearly regulated, low noise power supply
  • Low noise and drift current, temperature and piezo drivers
  • Supports numerous modules for laser stabilization
  • Modular setup for driving and locking various laser systems
  • All important controls directly accessible on front of modules

The diode laser supply rack DC 110 serves as a general basis for all plug-in modules of the SYS DC 110 series. It provides the necessary supply and HV voltages as well as communication lines via an integrated backplane. The monitor unit DC 110/Mon of the Diode Laser Controller displays the most relevant laser parameters at a glance for up to three laser systems.

The DCC 110 modules are low-noise, analog current control modules. Four different models deliver currents up to 100 mA, 500 mA, 3000 mA and 5000 mA. The DTC 110 is a low-noise temperature control module that regulates the laser diode temperature with a precision of approx. 1 mK. Special versions are available for DFB diodes and for regulating the temperature of nonlinear crystals. The SC 110 is optimized for driving ECDLs, DFBs or scanning Fabry-Perot interferometers. It can be configured in HV (150 V) or LV (24 V) mode. The “feed forward” feature controls the diode current during a Piezo scan to maximize the mode hop free tuning range of an ECDL system. The computer analog interface DCB 110 allows direct access to the backplane of the supply rack DC 110 for controlling the installed modules.

  • Specifications
    • DC 110 - Diode Laser Supply and Control Rack
      DC 110 - Diode Laser Supply and Control Rack    
      Model DC 110/12" DC 110/19" DC 110/19" DS DC 110/19" DS HP
      Space available 63 HP 84 HP 84 HP x2 84 HP x2
      Power requirements Typ < 120 W max. 300 W   max. 600 W
      Size (H x W x D) 150 x 355 x 385 mm³ 150 x 465 x 385 mm³ 280 x 465 x 385 mm³
      Voltage requirements automatic detection (100 - 120 or 220 - 240 VAC, 50 - 60 Hz)   
      Operating temperature 15 .. 30 °C   
      Transport temperature 0 .. 40 °C   
    • DC 110/Mon - Monitor Unit
      DC 110/Mon - Monitor Unit    
      DisplayFour line LCD dot matrix   
      ControlControl wheel for display configuration   
      ChannelsUp to three diode lasers supported   
      SafetySafety key switch, door interlock   
       safety button to start/stop emission   
      Width20 HP (102 mm)   
    • DCC 110 - Current Controllers
      DCC 110 - current controllers    
      ModelDCC 110/100 mADCC 110/500 mADCC 110/3 ADCC 110/5 A
      Output current range0 .. ± 100 mA0 .. ± 500 mA0 .. - 3 A0 .. - 5 A
      Constant current mode
      Constant power mode
      "current modulation bandwidth (-3 dB)"7 kHz7 kHz7 kHz7 kHz
      Current clip protection
      Voltage clip protection
      "RMS wideband noise and ripple (5 Hz .. 1 MHz)"200 nA1 µA10 µA40 µA
      Width12 HP (61 mm)12 (61 mm)12 (61 mm)32 HP (163 mm)
    • DTC 110 - Temperature Control Module
      DTC 110 - Temperature Control Module    
      ModelDTC 110 30WDTC 110 TO3DTC 110 SVL
      Intended useECDLsDFBsCrystals
      Max. TEC current2.5 A5 A5 A
      Temp. Selection range0 - 50 °C0 - 50 °C25 - 75 °C
      Over/under temp. protection
      Controlled heating/cooling ramp  
      Width 12 HP (61 mm)   
      Max. Power30 W   
      Long term stability (typ)1 .. 2 mK   
    • SC 110 - HV Scan Generator
      SC 110 - HV Scan Generator    
      Maximum output amplitude+ 24 V (LV mode)
      + 150 V (HV mode)
      Scan frequency range0.01 Hz - 10 kHz
      Output offset range-12 V .. +12 V (LV mode)
      -5 V .. + 150 V (HV mode)
      Signal shapesawtooth, symmetric or asymmetric ramps, variable
      Trigger unput / outputTTL, adjustable time delay
      Feed ForwardSimultaneous control of grating angle and laser current, adjustable ratio
    • DCB 110 - Analog Control Interface
      DCB 110 - Analog Control Interface    
      Current input sensitivty10 mA/V (DCC 110, 100 mA and 500 mA), 100 mA/V (DCC 110 / 3 A)
      Temperature input sensitivity10 deg C/V (DTC 110)
      Auxiliary supply voltages± 12 V, ± 5 V, GND (DCB 110 AUX only)
      ConnectorsSub-D25 connector, additional BNC connector to access selected backplane line
      Width4 HP (20 mm)