Date:
2009-07-13
Software
Version: 1.5.5.71
This file contains
information about the DigiLock 110 user interface software developed by TOPTICA
Photonics AG.
Contents
Processor: x86 platform (e.g. Pentium III,
4, M), min. 800 MHz,
recommended
> 1.2 GHz
RAM:
min.
256 MB, recommended 512 MB
Screen Resolution: min. 1024 x
768
Operating System: Windows 2000
SP4, Windows XP SP2, Windows
Interface: USB
1.1 or USB 2.0
To view the
user manual provided in the Help Menu, installation of Adobe Acrobat Reader® is necessary.
NOTE !
The installation of the USB-driver and the
control software requires administrator privileges.
Please uninstall any previously installed
DigiLock software. Otherwise the installations may interfere.
The
DigiLock 110 provides a USB connection to load the firmware and to control the
module via the supplied PC based software. In order to communicate with the
DigiLock 110, the USB driver has to be installed before the installation of the
application software. The driver is located in the directory “Drivers\USB” on
the installation CD supplied with the DigiLock 110 module. Run the .exe file to
install the driver on the PC.
After the
driver is installed successfully, connect the DigiLock 110 module to the PC
with the appropriate USB cable. The operating system will recognize the new
hardware.
Start the
program “setup.exe” in the folder “Installer” on the CD that is shipped
together with the DigiLock 110. The installer will guide you through the
installation process.
Version
1.5.4.70
·
Renaming
and repositioning of several front panel elements
·
Profile
and calibration data divided in two separate files
Version
1.1.3.40
·
Tab
with manual options for PID controllers is no longer present in AutoLock mode
when the “Advanced Settings” option is selected
·
MinMax
Intense option was renamed to Lock Window
·
Frequency
Analysis: the averaging algorithm now works with frequency spectra averaging
not any longer with averaging the time signals and performing the FFT
afterwards
Version
1.0.2.19
·
Files
containing device specific module settings are no longer stored in the
installation folder. They can be found in ...\Documents and Settings\<User
Name>\Application Data\Toptica\DigiLock\ (English Windows version) or
...\Dokumente und Einstellungen\<User
Name>\Anwendungsdaten\Toptica\DigiLock (German Windows version)
Version
1.5.4.70
·
Multi-Module
Support: up to 4 DigiLock modules can be operated on one computer
·
DigiLock
Module Server (DMS): administration of all connected DigiLock modules
·
Remote
Control Interface: the GUI and DMS can be controlled via TCP commands
·
Remote
Control Interface: full set of LabVIEW VIs is provided for easy integration of
the DigiLock in user applications
·
PID
Controllers: reset option with variable reset rates
·
PID
Controllers: relock performance improved when PID controller operates with high
derivative gain
·
Scope/Spectrum:
configurable smoothing function
·
Spectrum:
option to suppress the DC level
·
AutoLock
Mode: more detailed locking options
·
AutoLock
Mode/Display: more versatile selection of lock point in the graph
·
AutoLock
Mode/PID Controllers: reset option when input signal is out of supervision
window
·
LI
/ PDH: automatic phase adjustment
Version
1.1.3.40
·
AutoLock
Mode: when switching off the AutoLock and both PID controllers are involved the
controllers are switched off simultaneously not with a time delay of several
milliseconds
·
PID
Controllers: the behavior of the controller when switching off the lock (keep
PID value or reset PID) can be configured for both controllers
·
PID
Controllers: the input channel selection of the controllers is supervised. This
prevents from choosing the wrong input in case of top of fringe stabilization
(LI, PDH)
·
PID
Controllers: the delay time for the relock procedure is configurable
·
Scope
/ Frequency Analysis: PID 1 out and PID 2 out implemented as display traces
Version
1.0.2.19
·
Software
can be operated on non-administrator computer accounts
·
AutoLock
Mode: automatic adaptation of the timescale to the scanning frequency. The
“Timescale” control is no longer available
·
AutoLock
Mode: automatic tracking of the selected lockpoint
·
AutoLock
Mode: LI- or PDH-error signal is displayed in the graph
·
AutoLock:
relock options can be modified during the relock procedure
·
Scope
/ Frequency Analysis: overload indicators are turned on if the observed signals
reach its limits
·
Scope
/ Frequency Analysis: new signal available: error
·
Scope
/ AutoLock / Frequency Analysis: display of mean- and rms-value for both
channels
·
Network
Analyzer: the measurement can be stopped during acquisition
·
LI
/ PDH: offset for the error output can be set
·
Loading
user profiles with options
·
PID
Controllers: the output can be limited
·
PID
Controllers: during manual operation each controller has its own set of MinMax
Intense and Relock parameters
·
PID
Controllers: when using the MinMax Intense option the actual state (if the
selected channel is within its limits) can be monitored on the digital IO line
|
Bug-No. |
Discovered in version |
Description |
Status |
|
0001 |
1.0.1.17 |
PID-Controllers: The setpoint does not consider the analog
gain on the < |
fixed |
|
0002 |
1.0.1.17 |
Network Analyzer: The
maximum modulation amplitude is not limited (corresponding to the selected
output channel) |
fixed |
|
0003 |
1.0.1.17 |
Autolock: The MinMaxIntense
values do not consider the analog gain on the < |
fixed |
|
0004 |
1.0.1.17 |
PID-Controllers:
Trigger level do not consider the analog gain on
the < |
fixed |
|
0005 |
1.0.1.17 |
PID-Controllers: PID1
has 16 times less gain than PID2 with the same parameters |
fixed |
|
0006 |
1.0.2.19 |
PID-Controllers:
Parameters of the MinMaxIntense option were not updated when changing the analog gain on < |
fixed |
|
0007 |
1.0.2.19 |
Program Files were
copied write protected during installation |
fixed |
|
0008 |
1.0.2.19 |
Copying of Program
Files during software update did not work properly |
fixed |
|
0009 |
1.1.3.40 |
System Setup:
Parameters for fc and filter order are not updated
when modified in the simulation window |
fixed |
|
0010 |
1.1.3.40 |
Loading Profiles: It
is possible that after a profile is loaded all Function buttons disappear |
fixed |
|
0011 |
1.1.3.40 |
Autolock Display: Mouse-click in
the graph causes a change in offset and scan amplitude |
fixed |
|
0012 |
1.1.3.40 |
PID-Controllers: The
up-down arrow buttons of the gain parameter controls do not work properly |
fixed |
|
0013 |
1.1.3.40 |
Default values for some
controls are not reasonable |
fixed |
|
0014 |
1.5.4.70 |
Autolock Display: The wrong
context menu appeared in the graph |
fixed |
|
|
|
|
|